Skip to main content
OCADSAccess DataNDP-065NDP-065 - p16ap17a.dat (File 7), p17ep19s.dat (File 8), and p19c.dat (File 9)

8.5 p16ap17a.dat (File 7), p17ep19s.dat (File 8), and p19c.dat (File 9)

These files provide hydrographic, carbon dioxide, and chemical data for the all stations occupied during the R/V Knorr expeditions along WOCE Sections P16A/P17A, P17E/P19S, and P19C. Each record contains a station number, cast number, sample number, bottle number, CTD pressure, CTD temperature, CTD salinity, CTD oxygen, potential temperature, bottle salinity, oxygen, silicate, nitrate, nitrite, phosphate, CFC-11, CFC-12, TCO2, pCO2, pCO2 temperature, and data-quality flags. The files are sorted by station number and pressure and can be read by using the following FORTRAN 77 code [contained in data.for (File 3)]:

       CHARACTER qualt*13
       INTEGER sta, cast, samp, bot
       REAL pre, ctdtmp, ctdsal, ctdoxy, theta, sal, oxy, silca
       REAL nitrat, nitrit, phspht, cfc11, cfc12, tcarb, pco2
       REAL pco2tmp

      read (1, 10, end=999) sta, cast, samp, bot, pre, ctdtmp,
     1 ctdsal, ctdoxy, theta, sal, oxy, silca, nitrat, nitrit,
     2 phspht, cfc11, cfc12, tcarb, pco2, pco2tmp, qualt

 10    format (5X, I3, 7X, I1, 6X, I2, 6X, I2, 1X, F7.1, 1X, F7.4,
     1 1X, F7.4, 1X, F7.1, 1X, F7.4, 1X, F9.4, 1X, F7.1, 1X, F7.2,
     2 1X, F7.2, 1X, F7.2, 1X, F7.2, 1X, F8.3, 1X, F8.3, 1X, F7.1,
     3 1X, F7.2, 1X, F7.2, 1X, A13)

Stated in tabular form, the contents include the following:

Variable Variable type Variable width Starting column Ending column
sta Numeric 3 6 8
cast Numeric 1 16 16
samp Numeric 2 23 24
bot Numeric 2 31 32
pre Numeric 7 34 40
ctdtmp Numeric 7 42 48
ctdsal Numeric 7 50 56
ctdoxy Numeric 7 58 64
theta Numeric 7 66 72
sal Numeric 9 74 82
oxy Numeric 7 84 90
silca Numeric 7 92 98
nitrat Numeric 7 100 106
nitrit Numeric 7 108 114
phspht Numeric 7 116 122
cfc11 Numeric 8 124 131
cfc12 Numeric 8 133 140
tcarb Numeric 7 142 148
pco2 Numeric 7 150 156
pco2tmp Numeric 7 158 164
qualt Character 14 166 178

The variables defined as follows:

sta  =  the station number;
cast  =  the cast number;
samp  =  the sample number;
bota  =  the bottle number;
pre  =  the CTD pressure (in dbar);
ctdtmp  =  the CTD temperature (in °C);
ctdsala  =  the CTD salinity [on the Practical Salinity Scale (PSS)];
ctdoxya  =  the CTD oxygen concentration (in µmol/kg);
theta  =  the potential temperature (in °C);
sala  =  the bottle salinity (on the PSS);
oxya  =  the oxygen concentration (in µmol/kg);
silcaa  =  the silicate concentration (in µmol/kg);
nitrata  =  the nitrate concentration (in µmol/kg);
nitrita  =  the nitrite concentration (in µmol/kg);
phsphta  =  the phosphate concentration (in µmol/kg);
cfc11a  =  the trichlorofluoromethane-11 concentration (CCl3F) (in pmol/kg);
cfc12a  =  the dichlorodifluoromethane-12 concentration (CCl2F2) (in pmol/kg);
tcarba  =  the total carbon dioxide concentration (in µmol/kg);
pco2a  =  the partial pressure of CO2 (in µatm and measured at pco2tmp);
pco2tmp  =  the temperature of equilibration of the pCO2 samples in the equilibrator (in °C);
qualt  =  a 13-digit character variable that contains data-quality flag codes for parameters marked with an asterisk (*) in the output file.

aVariables that are underlined with asterisks in the data files to indicate they have a data-quality flag. Data-quality flags are defined as follows:

1  =  sample for this measurement was drawn from water bottle, but results of analyses were not received;
2  =  acceptable measurement;
3  =  questionable measurement;
4  =  bad measurement;
5  =  not reported;
6  =  mean of replicate measurements;
7  =  manual chromatographic peak measurement;
8  =  irregular digital chromatographic peak integration;
9  =  sample was not drawn for this measurement from this bottle.