NOTE
This means the buttons don’t respond, or the gui is in some way hung. This is not the same as Hopelessly Confused, which is an actual error triggered by a firmware bug.
- enter ‘pkill DAS.py’ at the command line
look for the processes,
- ‘ps -ef | grep ser_’
kill them,
- ‘pkill ser_asc’
- ‘pkill ser_bin’
look again to make sure they’re gone
- ‘ps -ef | grep ser_’
- ‘rm /home/adcp/flags/*’
- ‘ps -ef | grep DAS’
- ‘pkill DAS_while_logging.py’
- ‘pkill DAS_while_cruise.py’
find the kind of tty (serial) lines we’re using:
- ‘grep tty /home/adcp/config/sensor_cfg.py’
look at the permissions for the typs of serial lines used:
- ‘ls -l /dev/ttyS* ttyn* ttyR* tty_dgnc*’
if any do not have all read and all write permission:
- (as root) ‘chmod a+rw /dev/ttyS* ttyn* ttyR* tty_dgnc*’
- It should find the present cruise and go straight to the Control Tab.