Dissolved inorganic carbon (DIC), total alkalinity, pH on total scale, temperature, salinity, oxygen, nutrients and other measurements collected from discrete samples and profile observations during the R/V Ryofu Maru III cruise rf201801 (EXPOCODE 49UP20180110) in the North Pacific Ocean from 2018-01-10 to 2018-02-22 (NCEI Accession 0209261)
PACKAGE DESCRIPTION: This dataset includes discrete profile measurements of dissolved inorganic carbon (DIC), total alkalinity, pH on total scale, temperature, salinity, oxygen, nutrients and other measurements collected from discrete samples and profile observations during the R/V Ryofu Maru III cruise rf201801 (EXPOCODE 49UP20180110) in the North Pacific Ocean from 2018-01-10 to 2018-02-22.
CITE AS: Tsubaki, Shuji; Nemoto, Kazuhiro; Ishii, Masao (2020). Dissolved inorganic carbon (DIC), total alkalinity, pH on total scale, temperature, salinity, oxygen, nutrients and other measurements collected from discrete samples and profile observations during the R/V Ryofu Maru III cruise rf201801 (EXPOCODE 49UP20180110) in the North Pacific Ocean from 2018-01-10 to 2018-02-22 (NCEI Accession 0209261). [indicate subset used]. NOAA National Centers for Environmental Information. Dataset. https://doi.org/10.25921/40v3-1h74. Accessed [date].
Discrete measurement;Profile;
TEMPORAL COVERAGE:
SPATIAL COVERAGE:
GEOGRAPHIC NAMES:
PLATFORMS:
RESEARCH PROJECT(S):
VARIABLES / PARAMETERS:
Dissolved Inorganic Carbon | |
---|---|
Abbreviation: | TCARBN |
Unit: | UMOL/KG |
Observation type: | discrete |
In-situ / Manipulation / Response variable: | In-situ observation |
Measured or calculated: | Measured |
Sampling instrument: | Niskin Bottles |
Quality flag convention: | WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value |
Total Alkalinity | |
---|---|
Abbreviation: | ALKALI |
Unit: | UMOL/KG |
Observation type: | discrete |
Sampling instrument: | Niskin Bottles |
Quality flag convention: | WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value |
pH on total scale | |
---|---|
Abbreviation: | PH_TOT |
Observation type: | discrete |
Sampling instrument: | Niskin Bottles |
Quality flag convention: | WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value |
CTD Temperature | |
---|---|
Abbreviation: | CTDTMP |
Unit: | degrees celcius |
Observation type: | CTD sensor |
Sampling instrument: | CTD |
Analyzing instrument: | CTD Sensor |
Quality flag convention: | WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value |
CTD Salinity | |
---|---|
Abbreviation: | CTDSAL |
Observation type: | CTD sensor |
Sampling instrument: | CTD |
Analyzing instrument: | CTD sensor |
Quality flag convention: | WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value |
CTD Dissolved Oxygen | |
---|---|
Abbreviation: | CTDOXY |
Unit: | UMOL/KG |
Observation type: | CTD, profile |
Sampling instrument: | CTD |
Quality flag convention: | WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value |
Salinity | |
---|---|
Abbreviation: | SALNTY |
Observation type: | Discrete, bottle |
Sampling instrument: | Niskin Bottles |
Quality flag convention: | WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value |
Dissolved Oxygen | |
---|---|
Abbreviation: | OXYGEN |
Unit: | UMOL/KG |
Observation type: | Discrete, bottle |
Sampling instrument: | Niskin Bottles |
Quality flag convention: | WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value |
silicate, nitrat, nitrit, phosphate | |
---|---|
Abbreviation: | Nutrients |
Unit: | UMOL/KG |
Observation type: | Discrete, bottle |
Sampling instrument: | Niskin Bottles |
Quality flag convention: | WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value |
SUBMITTED BY: Robert M. Key (key@princeton.edu)
SUBMISSION DATE: 2020-03-09