Partial pressure (or fugacity) of carbon dioxide, salinity, temperature and chlorophyll collected from surface underway observations during the yacht Turn the Tide on Plastic Volvo Ocean 65 (VO65) Race cruises in the Atlantic Ocean, Pacific Ocean, Indian Ocean, North Sea, English Channel, Philippine Sea, South China Sea, Tasman Sea and Mediterranean Sea from 2017-10-22 to 2018-07-07 (NCEI Accession 0191505)
PACKAGE DESCRIPTION: This dataset includes surface underway data collected during the yacht Turn the Tide on Plastic Volvo Ocean 65 (VO65) Race cruises in the Atlantic Ocean, Pacific Ocean, Indian Ocean, North Sea, English Channel, Philippine Sea, South China Sea, Tasman Sea and Mediterranean Sea from 2017-10-22 to 2018-07-07. These data include partial pressure (or fugacity) of carbon dioxide in the water, sea surface salinity and sea surface temperature. The instruments used to collect these data include carbon dioxide (CO2) gas analyzer, shower head chamber equilibrator for autonomous carbon dioxide (CO2) measurement.
CITE AS: Gutekunst, Sören; Tanhua, Toste (2019). Partial pressure (or fugacity) of carbon dioxide, salinity, temperature and chlorophyll collected from surface underway observations during the yacht Turn the Tide on Plastic Volvo Ocean 65 (VO65) Race cruises in the Atlantic Ocean, Pacific Ocean, Indian Ocean, North Sea, English Channel, Philippine Sea, South China Sea, Tasman Sea and Mediterranean Sea from 2017-10-22 to 2018-07-07 (NCEI Accession 0191505). [indicate subset used]. NOAA National Centers for Environmental Information. Dataset. https://doi.org/10.25921/ghja-1m54. Accessed [date].
none;
Surface measurement;Surface underway;
TEMPORAL COVERAGE:
SPATIAL COVERAGE:
GEOGRAPHIC NAMES:
PLATFORMS:
RESEARCH PROJECT(S):
VARIABLES / PARAMETERS:
pCO2 (fCO2) autonomous | |
---|---|
Abbreviation: | xCO2 |
Unit: | ppm |
Observation type: | Surface underway |
Measured or calculated: | Measured |
Sampling instrument: | Seawater pump |
Analyzing instrument: | Li-804A |
Detailed sampling and analyzing information: | membrane |
Equilibrator type: | Flat membrane (PDMS) |
Equilibrator volume: | 1885 mm2 |
Is the equilibrator vented or not: | closed loop |
Water flow rate: | 8 L/min |
Gas flow rate: | 0.5 L/min |
Drying method for gas: | measuring in wet atmosphere |
SEA CO2 gas detector manufacturer: | Licor, Inc |
SEA CO2 gas detector model: | LI-840A |
SEA CO2 gas detector uncertainty: | better than 1% of reading, zero drift less than 0.15 ppm/°C, span drift less than 0.03 %/°C |
Standardization technique: | Calibration with 451.1 ppm gas from Deuste Steininger. Calibration 06.2018 |
Standard gas manufacturer: | Idronaut (TSG); TriOS (Fluorimeter) |
Sea Surface Temperature | |
---|---|
Abbreviation: | SST_C |
Unit: | degrees celcius |
Observation type: | Surface Underway |
Analyzing instrument: | Idronaut (TSG), Ocean Seven 304Plus |
Uncertainty: | 0.0001 °C |
Sea Surface Salinity | |
---|---|
Abbreviation: | SSS |
Observation type: | Surface Underway |
Chlorophyll | |
---|---|
Abbreviation: | Chlorophyll |
Unit: | mgPerm3 |
Observation type: | Surface Underway |
Analyzing instrument: | TriOS (Fluorimeter), Trios MicroFlu/NanoFlu |
SUBMITTED BY: Sören Gutekunst (sgutekunst@geomar.de)
SUBMISSION DATE: 2019-06-06