Characteristics of the carbonate system in a Semi-Arid Estuary, that experiences summertime hypoxia based on chemical and physical data collected in Corpus Christi Bay, Gulf of Mexico in 2015-2016 (NCEI Accession 0189592)
PACKAGE DESCRIPTION: This dataset includes estuarine water physical (salinity, temperature, water depth) and chemical parameters (total dissolved inorganic carbon, total alkalinity, pH on total scale observed at 25˚C, dissolved oxygen concentration, ammonia, soluble reactive phosphate and silicate) in the semiarid Corpus Christi Bay, the northwestern Gulf of Mexico. The sample collections were done in June-August 2015 and June-September 2016. This dataset is described in the submitted article "Characteristics of the Carbonate System in a Semi-Arid Estuary that Experiences Summertime Hypoxia" by Melissa R. McCutcheon, Cory J. Staryk, Xinping Hu (https://doi.org/10.1007/s12237-019-00588-0) in the Journal Estuaries and Coasts.
CITE AS: Hu, Xinping; McCutcheon, Melissa R.; Staryk, Cory (2019). Characteristics of the carbonate system in a Semi-Arid Estuary, that experiences summertime hypoxia based on chemical and physical data collected in Corpus Christi Bay, Gulf of Mexico in 2015-2016 (NCEI Accession 0189592). [indicate subset used]. NOAA National Centers for Environmental Information. Dataset. https://doi.org/10.25921/gh54-9h50. Accessed [date].
none;
Discrete measurement;
TEMPORAL COVERAGE:
SPATIAL COVERAGE:
GEOGRAPHIC NAMES:
PLATFORMS:
RESEARCH PROJECT(S):
VARIABLES / PARAMETERS:
Dissolved Inorganic Carbon | |
---|---|
Abbreviation: | TCARBN |
Unit: | µmol/kg |
Observation type: | Laboratory experiment |
Measured or calculated: | Measured |
Sampling instrument: | 8.2 L Van Dorn bottle |
Analyzing instrument: | Apollo AS-C3 |
Replicate information: | Random duplicate sample collection |
Standardization description: | Certified Reference Materials |
Standardization frequency: | Daily |
CRM manufacturer: | Andrew Dickson's laboratory at Scripps Institute of Oceanography |
CRM batch number: | 146, 147, 148, 156 |
Preservation method: | Saturated HgCl2 |
Preservative volume: | 100 µL |
Preservative correction: | Results are corrected for 0.04% due to the addition of HgCl2 solution |
Uncertainty: | ±0.1% |
Quality flag convention: | WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value |
Method reference: | Hu, X., M.F. Nuttall, H. Wang, H. Yao, C.J. Staryk, M.R. McCutcheon, R.J. Eckert, J.A. Embesi, M.A. Johnston, E.L. Hickerson, G.P. Schmahl, D. Manzello, I.C. Enochs, S. DiMarco, and L. Barbero. 2018. Seasonal variability of carbonate chemistry and decadal changes in waters of a marine sanctuary in the Northwestern Gulf of Mexico. Marine Chemistry 205: 16-28. |
Researcher name: | Cory J. Staryk, Melissa R. McCutcheon |
Researcher institution: | Texas A&M University-Corpus Christi |
Total alkalinity | |
---|---|
Abbreviation: | TA |
Unit: | µmol/kg |
Observation type: | Laboratory experiment |
Measured or calculated: | Measured |
Sampling instrument: | 8.2 L Van Dorn bottle |
Analyzing instrument: | Apollo AS-ALK2 |
Type of titration: | Potentiometric |
Cell type (open or closed): | open |
Curve fitting method: | Gran |
Replicate information: | Ramdon duplicate sample collection |
Standardization description: | Certified Reference Materials |
Standardization frequency: | Daily |
CRM manufacturer: | Andrew Dickson's lab at Scripps Institute of Oceanography |
CRM batch number: | CRM batch 146, 147, 148, 156 |
Preservation method: | Saturated HgCl2 |
Preservative volume: | 100 µL |
Preservative correction: | Results are corrected for 0.04% due to the addition of HgCl2 solution |
Uncertainty: | ±0.1% |
Quality flag convention: | WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value |
Method reference: | Hu, X., M.F. Nuttall, H. Wang, H. Yao, C.J. Staryk, M.R. McCutcheon, R.J. Eckert, J.A. Embesi, M.A. Johnston, E.L. Hickerson, G.P. Schmahl, D. Manzello, I.C. Enochs, S. DiMarco, and L. Barbero. 2018. Seasonal variability of carbonate chemistry and decadal changes in waters of a marine sanctuary in the Northwestern Gulf of Mexico. Marine Chemistry 205: 16-28. |
Researcher name: | Cory J. Staryk, Melissa R. McCutcheon |
Researcher institution: | Texas A&M University-Corpus Christi |
pH | |
---|---|
Abbreviation: | pH |
pH scale: | Total (NBS scale for salinity less than 20) |
Observation type: | Discrete, bottle |
Measured or calculated: | Measured |
Sampling instrument: | 8.2 L Van Dorn bottle |
Analyzing instrument: | Agilent 8453 |
Temperature of pH measurement: | 25°C |
Detailed sampling and analyzing information: | Spectrophotometric (potentiometric for salinity less than 20) |
Replicate information: | Random duplicate sample collection |
Standardization description: | Purified mCP was used in the spectrophotometric analysis; Thermo Fisher 4.01, 7.00, 10.01 pH buffers were used for low salinity samples (salinity less than 20) |
At what temperature was pH reported: | 25°C |
Uncertainty: | ±0.0005 (±0.01 for salinity less than 20) |
Quality flag convention: | WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value |
Method reference: | Carter, B.R., J.A. Radich, H.L. Doyle, and A.G. Dickson. 2013. An automatic system for spectrophotometric seawater pH measurements. Limnology and Oceanography: Methods 11: 16-27. |
Researcher name: | Cory J. Staryk, Melissa R. McCutcheon |
Researcher institution: | Texas A&M University-Corpus Christi |
Sample Depth | |
---|---|
Abbreviation: | Depth |
Unit: | m |
Uncertainty: | ±0.1 |
Field temperature | |
---|---|
Abbreviation: | Temp |
Unit: | ˚C |
Uncertainty: | ±0.1 |
Salinity | |
---|---|
Abbreviation: | Salinity |
Uncertainty: | ±0.1 |
Dissolved calcium concentration | |
---|---|
Abbreviation: | Ca2+ |
Unit: | mmol/kg |
Uncertainty: | ±0.2% |
total ammonia concentration | |
---|---|
Abbreviation: | NHx |
Unit: | µmol/kg |
Uncertainty: | ±0.03 |
Soluble reactive phosphate | |
---|---|
Abbreviation: | PO4 |
Unit: | µmol/kg |
Uncertainty: | ±0.01 |
Dissolved silicate | |
---|---|
Abbreviation: | SiO4 |
Unit: | µmol/kg |
Uncertainty: | ±0.07 |
Dissolved oxygen | |
---|---|
Abbreviation: | DO |
Unit: | µmol/kg |
Uncertainty: | ±2% |
SUBMITTED BY: Xinping Hu (xinping.hu@tamucc.edu)