Dissolved inorganic carbon (DIC), total alkalinity, pH on total scale, temperature, salinity, oxygen, nutrients and other measurements collected from profile and discrete sample observations during the R/V Ryofu Maru III cruise RF09-09 (EXPOCODE 49UP20090916) in the North Pacific Ocean from 2009-09-16 to 2009-11-11 (NCEI Accession 0186284)
PACKAGE DESCRIPTION: This dataset includes discrete profile measurements of dissolved inorganic carbon (DIC), total alkalinity, pH on total scale, temperature, salinity, oxygen and nutrients collected during the R/V Ryofu Maru III cruise RF09-09 (EXPOCODE 49UP20090916) in the North Pacific Ocean from 2009-09-16 to 2009-11-11.
CITE AS: Kamiya, Hitomi; Minato, Shinya; Ishii, Masao (2019). Dissolved inorganic carbon (DIC), total alkalinity, pH on total scale, temperature, salinity, oxygen, nutrients and other measurements collected from profile and discrete sample observations during the R/V Ryofu Maru III cruise RF09-09 (EXPOCODE 49UP20090916) in the North Pacific Ocean from 2009-09-16 to 2009-11-11 (NCEI Accession 0186284). [indicate subset used]. NOAA National Centers for Environmental Information. Dataset. https://doi.org/10.25921/9t5m-de80. Accessed [date].
Discrete measurement;
TEMPORAL COVERAGE:
SPATIAL COVERAGE:
GEOGRAPHIC NAMES:
PLATFORMS:
RESEARCH PROJECT(S):
VARIABLES / PARAMETERS:
Dissolved Inorganic Carbon | |
---|---|
Abbreviation: | TCARBN |
Unit: | UMOL/KG |
Observation type: | discrete |
In-situ / Manipulation / Response variable: | In-situ observation |
Measured or calculated: | Measured |
Sampling instrument: | Niskin Bottles |
Quality flag convention: | WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value |
Total alkalinity | |
---|---|
Abbreviation: | ALKALI |
Unit: | UMOL/KG |
Observation type: | discrete |
Sampling instrument: | Niskin Bottles |
Quality flag convention: | WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value |
pH on total scale | |
---|---|
Abbreviation: | PH_TOT |
Observation type: | discrete |
Sampling instrument: | Niskin Bottles |
Quality flag convention: | WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value |
CTD Temperature | |
---|---|
Abbreviation: | CTDTMP |
Unit: | degrees celcius |
Observation type: | CTD sensor |
Sampling instrument: | CTD |
Analyzing instrument: | CTD Sensor |
Quality flag convention: | WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value |
CTD Salinity | |
---|---|
Abbreviation: | CTDSAL |
Observation type: | CTD sensor |
Sampling instrument: | CTD |
Analyzing instrument: | CTD sensor |
Quality flag convention: | WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value |
Salinity | |
---|---|
Abbreviation: | SALNTY |
Observation type: | Discrete, bottle |
Sampling instrument: | Niskin Bottles |
Quality flag convention: | WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value |
Dissolved Oxygen | |
---|---|
Abbreviation: | OXYGEN |
Unit: | UMOL/KG |
Observation type: | Discrete, bottle |
Sampling instrument: | Niskin Bottles |
Quality flag convention: | WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value |
silicate, nitrat, nitrit, phosphate | |
---|---|
Abbreviation: | Nutrients |
Unit: | UMOL/KG |
Observation type: | Discrete, bottle |
Sampling instrument: | Niskin Bottles |
Quality flag convention: | WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value |
SUBMITTED BY: Nico Lange (nlange@geomar.de)
SUBMISSION DATE: 2018-11-30
REVISION DATE: 2020-02-03
PREVIOUS VERSIONS: Version 1.1