Skip to main content

Dissolved inorganic carbon (DIC), pH on total scale, temperature, salinity, oxygen, nutrients and other measurements collected from profile and discrete sample observations during the R/V Ryofu Maru III cruise RF09-01 (EXPOCODE 49UP20090117) in the Pacific Ocean from 2009-01-16 to 2009-03-10 (NCEI Accession 0186283)

INVESTIGATORS:
Yumitoshi Miura - JMA, Japan
Masao Ishii ORCID logo - Japan Meteorological Agency; Meteorological Research Institute (MRI)

PACKAGE DESCRIPTION: This dataset includes discrete profile measurements of dissolved inorganic carbon (DIC), pH on total scale, temperature, salinity, oxygen and nutrients collected during the R/V Ryofu Maru III cruise RF09-01 (EXPOCODE 49UP20090117) in the Pacific Ocean from 2009-01-16 to 2009-03-10.

CITE AS: Miura, Yumitoshi; Minato, Shinya; Ishii, Masao (2019). Dissolved inorganic carbon (DIC), pH on total scale, temperature, salinity, oxygen, nutrients and other measurements collected from profile and discrete sample observations during the R/V Ryofu Maru III cruise RF09-01 (EXPOCODE 49UP20090117) in the Pacific Ocean from 2009-01-16 to 2009-03-10 (NCEI Accession 0186283). [indicate subset used]. NOAA National Centers for Environmental Information. Dataset. https://doi.org/10.25921/y6v3-fj36. Accessed [date].


DATA PACKAGES RELATED TO THIS ONE:
none;
IDENTIFICATION INFORMATION FOR THIS DATA PACKAGE:
NCEI ACCESSION: 0186283
NCEI DOI: https://doi.org/10.25921/y6v3-fj36
EXPOCODE: 49UP20090117;
CRUISE ID: RF09-01;
SECTION/LEG: P09;

TYPES OF STUDY:
Discrete measurement;

TEMPORAL COVERAGE:
START DATE: 2009-01-16
END DATE: 2009-03-10

SPATIAL COVERAGE:
NORTH: 35
WEST: 137
EAST: 165.4
SOUTH: -5.3

GEOGRAPHIC NAMES:
Pacific Ocean;

PLATFORMS:
R/V Ryofu Maru (ID: 49UP);

RESEARCH PROJECT(S):
none;


VARIABLES / PARAMETERS:

Dissolved Inorganic Carbon
Abbreviation: TCARBN
Unit: UMOL/KG
Observation type: discrete
In-situ / Manipulation / Response variable: In-situ observation
Measured or calculated: Measured
Sampling instrument: Niskin Bottles
Quality flag convention: WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value
pH on total scale
Abbreviation: PH_TOT
Observation type: discrete
Sampling instrument: Niskin Bottles
Quality flag convention: WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value
CTD Temperature
Abbreviation: CTDTMP
Unit: degrees celcius
Observation type: CTD sensor
Sampling instrument: CTD
Analyzing instrument: CTD Sensor
Quality flag convention: WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value
CTD Salinity
Abbreviation: CTDSAL
Observation type: CTD sensor
Sampling instrument: CTD
Analyzing instrument: CTD sensor
Quality flag convention: WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value
Salinity
Abbreviation: SALNTY
Observation type: Discrete, bottle
Sampling instrument: Niskin Bottles
Quality flag convention: WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value
Dissolved Oxygen
Abbreviation: OXYGEN
Unit: UMOL/KG
Observation type: Discrete, bottle
Sampling instrument: Niskin Bottles
Quality flag convention: WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value
silicate, nitrat, nitrit, phosphate
Abbreviation: Nutrients
Unit: UMOL/KG
Observation type: Discrete, bottle
Sampling instrument: Niskin Bottles
Quality flag convention: WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value

PUBLICATIONS DESCRIBING THIS DATASET:
none;
ADDITIONAL INFORMATION:
none;
FUNDING AGENCY:

SUBMITTED BY: Nico Lange (nlange@geomar.de)

SUBMISSION DATE: 2018-11-30

REVISION DATE: 2020-01-31

PREVIOUS VERSIONS: Version 1.1