Skip to main content

Discrete profile measurements of dissolved inorganic carbon, total alkalinity and other hydrographic and chemical data during the R/V Meteor cruise M116/1 (EXPOCODE 06M320150501) in the Tropical Atlantic Ocean from 2015-05-01 to 2015-06-03 (NCEI Accession 0170657)

INVESTIGATORS:
Martin Visbeck - Leibniz Institute of Marine Sciences (IFM-GEOMAR)
Toste Tanhua ORCID logo - GEOMAR Helmholtz Centre for Ocean Research Kiel, Kiel, Germany
Arne Körtzinger ORCID logo - GEOMAR Helmholtz Centre for Ocean Research Kiel, Kiel, Germany

PACKAGE DESCRIPTION: This dataset includes profile discrete profile measurements of dissolved inorganic carbon (DIC), total alkalinity, temperature, salinity, oxygen, nutrients and CFCs obtained during the R/V Meteor cruise M116/1 (EXPOCODE 06M320150501) in the Tropical Atlantic Ocean from 2015-05-01 to 2015-06-03.

CITE AS: Visbeck, Martin; Tanhua, Toste; Körtzinger, Arne; Schmidtko, Sunke (2018). Discrete profile measurements of dissolved inorganic carbon, total alkalinity and other hydrographic and chemical data during the R/V Meteor cruise M116/1 (EXPOCODE 06M320150501) in the Tropical Atlantic Ocean from 2015-05-01 to 2015-06-03 (NCEI Accession 0170657). [indicate subset used]. NOAA National Centers for Environmental Information. Dataset. https://doi.org/10.7289/v5qc01tk. Accessed [date].


DATA PACKAGES RELATED TO THIS ONE:
IDENTIFICATION INFORMATION FOR THIS DATA PACKAGE:
NCEI ACCESSION: 0170657
NCEI DOI: https://doi.org/10.7289/v5qc01tk
EXPOCODE: 06M320150501;
CRUISE ID: M116/1;
SECTION/LEG: A06;

TYPES OF STUDY:
Discrete measurement;

TEMPORAL COVERAGE:
START DATE: 2015-05-01
END DATE: 2015-06-03

SPATIAL COVERAGE:
NORTH: 15
WEST: -58.6
EAST: -17.6
SOUTH: 3.9

GEOGRAPHIC NAMES:
Atlantic Ocean;

PLATFORMS:
R/V Meteor (ID: 06M3);

RESEARCH PROJECT(S):
none;


VARIABLES / PARAMETERS:

Dissolved Inorganic Carbon
Abbreviation: TCARBN
Unit: UMOL/KG
Observation type: Discrete, bottle
Measured or calculated: Measured
Analyzing instrument: SOMMA (single operator multi-parameter metabolic analyzer) system, which is based on coulometric titration of the CO2 evolved from the seawater sample upon acidification with phosphoric acid (Johnson et al., 1993)
Replicate information: DIC was determined from 1246 samples at 66 stations. A total amount of 107 duplicates (σ = 1.30 μmol/kg) and 8 triplicates (σ = 0.65 μmol/kg) were taken and 105 CRMs were measured in order to determine accuracy and precision.
CRM manufacturer: Andrew Dickson Laboratory at SIO
CRM batch number: Batch 142 and 143
Preservation method: mercuric chloride solution
Preservative volume: 100 mL
Uncertainty: precision was better than 2 micromol kg-1
Quality flag convention: WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value
Method reference: Johnson, K.M., Wills, K.D., Butler, D.B., Johnson, W.K., and Wong, C.S. (1993). Coulometric total carbon dioxide analysis for marine studies: Maximizing the performance of an automated continuous gas extraction system and coulometric detector. Marine Chemistry, 44, pp 167-189.
Researcher name: Arne Körtzinger
Researcher institution: GEOMAR Germany
Total alkalinity
Abbreviation: ALKALI
Unit: UMOL/KG
Observation type: Discrete, bottle
Measured or calculated: Measured
Analyzing instrument: Semi-automatic analyzer called VINDTA (Versatile Instrument for the Determination of Titration Alkalinity).
Type of titration: potentiometric titration
Cell type (open or closed): open
Standardization description: TA was determined from 1246 samples at 66 stations. A total amount of 108 duplicates (σ = 2.73 μmo/kg)and 9 triplicates (σ = 2.02 μmol/kg) were taken and 122 CRM’s were measured in order to determine accuracy and precision.
CRM batch number: Batch 142 and 143
Quality flag convention: WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value
Method reference: Dickson, Andrew G., Chris Sabine and James R. Christian, editors, "Guide to Best Practices for Ocean CO2 Measurements", Pices Special Publication 3, IOCCP Report No. 8, October 2007, SOP 3b, "Determination of total alkalinity in sea water using an open-cell titration"
Researcher name: Arne Körtzinger
Researcher institution: GEOMAR Germany
CTD Temperature
Abbreviation: CTDTMP
Unit: degrees celcius
Observation type: CTD sensor
Sampling instrument: CTD
Analyzing instrument: CTD
Quality flag convention: WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value
Researcher name: Sunke Schmidtko
Researcher institution: GEOMAR Germany
CTD Salinity
Abbreviation: CTDSAL
Observation type: CTD sensor
Sampling instrument: CTD
Analyzing instrument: CTD
Quality flag convention: WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value
Researcher name: Sunke Schmidtko
Researcher institution: GEOMAR Germany
Bottle Salinity
Abbreviation: SALNTY
Observation type: Bottle, discrete
Sampling instrument: CTD
Quality flag convention: WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value
Researcher name: Martin Visbeck
Researcher institution: GEOMAR Germany
CTD Oxygen
Abbreviation: CTDOXY
Unit: UMOL/KG
Observation type: CTD sensor
Sampling instrument: CTD
Quality flag convention: WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value
Researcher name: Sunke Schmidtko
Researcher institution: GEOMAR Germany
Bottle Oxygen
Abbreviation: OXYGEN
Unit: UMOL/KG
Observation type: Bottle, discrete
Sampling instrument: CTD
Quality flag convention: WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value
Researcher name: Toste Tanhua;
Researcher institution: GEOMAR Germany
Nutrients
Abbreviation: SILCAT, NITRAT, NITRIT, PHSPHT
Unit: UMOL/KG
Observation type: Bottle, discrete
Sampling instrument: CTD
Quality flag convention: WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value
Researcher name: Toste Tanhua;
Researcher institution: GEOMAR Germany
CFC
Abbreviation: CFC
Unit: PMOL/KG
Observation type: Bottle, discrete
Sampling instrument: CTD bottles
Quality flag convention: WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value
Researcher name: Toste Tanhua;
Researcher institution: GEOMAR Germany

PUBLICATIONS DESCRIBING THIS DATASET:
none;
ADDITIONAL INFORMATION:
none;
FUNDING AGENCY:
Deutsche Forschungsgemeinschaft (DFG) and the Bundesministerium für Bildung und Forschung (BMBF)
PROJECT TITLE: Oxygen in the Tropical Atlantic
PROJECT ID:

SUBMITTED BY: Robert M. Key (key@princeton.edu)

SUBMISSION DATE: 2018-02-15

REVISION DATE: 2018-03-28