Surface underway pCO2 measurements aboard the RRS Discovery during the Atlantic Meridional Transect (AMT21) cruise from 2011-10-03 to 2011-11-09 (NCEI Accession 0170365)
PACKAGE DESCRIPTION: This dataset includes surface underway data collected aboard the RRS Discovery during the Atlantic Meridional Transect (AMT21) cruise from 2011-10-03 to 2011-11-09. These data include partial pressure (or fugacity) of carbon dioxide - atmosphere, partial pressure (or fugacity) of carbon dioxide - water, sea surface salinity, sea surface temperature and barometric pressure. The instruments used to collect these data include carbon dioxide (CO2) gas analyzer, shower head chamber equilibrator for autonomous carbon dioxide (CO2) measurement. These data were collected by Vassilis Kitidis of Plymouth Marine Laboratory.
CITE AS: Kitidis, Vassilis (2018). Surface underway pCO2 measurements aboard the RRS Discovery during the Atlantic Meridional Transect (AMT21) cruise from 2011-10-03 to 2011-11-09 (NCEI Accession 0170365). [indicate subset used]. NOAA National Centers for Environmental Information. Dataset. https://doi.org/10.7289/v5pz5733. Accessed [date].
none;
Surface measurement;Surface underway;
TEMPORAL COVERAGE:
SPATIAL COVERAGE:
GEOGRAPHIC NAMES:
PLATFORMS:
RESEARCH PROJECT(S):
VARIABLES / PARAMETERS:
pCO2 (fCO2) autonomous | |
---|---|
Abbreviation: | pCO2_sw |
Unit: | uatm |
Observation type: | Surface underway |
Measured or calculated: | Measured |
Sampling instrument: | Seawater pump |
Location of seawater intake: | Hull |
Analyzing instrument: | Dartcom-PML LivepCO2 |
Detailed sampling and analyzing information: | Non Dispersive IR Sensor |
Equilibrator type: | Headspace (vented) |
Equilibrator volume: | 2.5 L |
Is the equilibrator vented or not: | Vented |
Water flow rate: | 1.6 L/min |
Gas flow rate: | 200 mL/min |
Drying method for gas: | Peltier drier to 20% humidity |
SEA CO2 gas detector manufacturer: | Licor, Inc |
SEA CO2 gas detector model: | LI-840 |
SEA CO2 gas detector resolution: | Accuracy: 2 micro-atm fCO2 |
SEA CO2 gas detector uncertainty: | Precision: 0.5 micro-atm fCO2 |
Standardization technique: | Sensor calibration during deployment using 3 gas standards (nominally 250; 380 and 450 ppmv CO2 in synthetic air) |
Standard gas manufacturer: | BOC gases Ltd., |
Standard gas concentration: | nominally 250; 380 and 450 ppmv CO2 in synthetic air |
At what temperature was pCO2 reported: | In situ sea surface temperature |
Method reference: | Ribas-Ribas et al. 2014. Intercomparison of carbonate chemistry measurements on a cruise in northwestern European shelf seas. Biogeosciences. 11: 4339-4355 |
Researcher name: | Vassilis Kitidis |
Researcher institution: | Plymouth Marine Laboratory |
Sea Surface Temperature | |
---|---|
Abbreviation: | SST_C |
Unit: | degrees celcius |
Observation type: | Surface Underway |
Analyzing instrument: | SBE 45 (serial #: 0229) |
Detailed sampling and analyzing information: | Manufacturer: SeaBird Electronics |
Uncertainty: | Accuracy and Precision: 0.001C |
Researcher name: | Vassilis Kitidis |
Researcher institution: | Plymouth Marine Laboratory |
Sea Surface Salinity | |
---|---|
Abbreviation: | SSS |
Observation type: | Surface Underway |
Sampling instrument: | Intake salinity sensor, Seabird |
Analyzing instrument: | SBE 45 (serial #: 0229) |
Uncertainty: | 0.002 |
Researcher name: | Vassilis Kitidis |
Researcher institution: | Plymouth Marine Laboratory |
Atmospheric pressure at sea-surface pressure | |
---|---|
Abbreviation: | AtmPrs |
Unit: | hPa |
Observation type: | Underway |
Analyzing instrument: | PTB110 barometer, Vaisala |
Uncertainty: | 1 hPa |
Researcher name: | Vassilis Kitidis |
Researcher institution: | Plymouth Marine Laboratory |
SUBMITTED BY: Vassilis Kitidis (vak@pml.ac.uk)
SUBMISSION DATE: 2018-01-16