Dissolved Inorganic Carbon (DIC), Total Alkalinity, Oxygen and other Hydrographic and Chemical Data Obtained During R/V Polarstern Cruise ARKXXVII/1 (EXPOCODE 06AQ20120614) along the CLIVAR Repeat Section 75N in the North Atlantic Ocean from 2012-06-14 to 2012-07-15 (NCEI Accession 0162432)
PACKAGE DESCRIPTION: This dataset includes discrete bottle measurements of Dissolved Inorganic Carbon (DIC), Total Alkalinity, temperature, salinity, oxygen and CFCs from R/V Polarstern Cruise ARKXXVII/1 (EXPOCODE 06AQ20120614) in the North Atlantic Ocean, Section 75N, from 2012-06-14 to 2012-07-15. The R/V Polarstern ARKXXVII/1 cruise is a part of the CLIVAR/GO-SHIP Repeat Sections observations from the research ships along the section 75N. This work was supported by the Deutsche Forschungsgemeinschaft (DFG) in the framework of the priority program Antarctic Research with comparative investigations in Arctic ice area by a grant to T. Tanhua and M. Hoppema: Carbon and 25 transient tracers dynamics: A bi-polar view on Southern Ocean eddies and the changing Arctic Ocean (TA 317/5, HO 4680/1)
CITE AS: Tanhua, Toste; Hoppema, Mario (2017). Dissolved Inorganic Carbon (DIC), Total Alkalinity, Oxygen and other Hydrographic and Chemical Data Obtained During R/V Polarstern Cruise ARKXXVII/1 (EXPOCODE 06AQ20120614) along the CLIVAR Repeat Section 75N in the North Atlantic Ocean from 2012-06-14 to 2012-07-15 (NCEI Accession 0162432). [indicate subset used]. NOAA National Centers for Environmental Information. Dataset. https://doi.org/10.7289/v5tt4p5v. Accessed [date].
none;
Discrete measurement;
TEMPORAL COVERAGE:
SPATIAL COVERAGE:
GEOGRAPHIC NAMES:
PLATFORMS:
RESEARCH PROJECT(S):
VARIABLES / PARAMETERS:
Dissolved Inorganic Carbon | |
---|---|
Abbreviation: | TCARBN |
Unit: | UMOL/KG |
Observation type: | Discrete, bottle |
Measured or calculated: | Measured |
Analyzing instrument: | coulometric measurement system (SOMMA) |
CRM manufacturer: | Andrew Dickson Laboratory at SIO |
Preservation method: | mercuric chloride solution |
Preservative volume: | 100 mL |
Uncertainty: | +/- 1.1 UMOL/KG |
Quality flag convention: | WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value |
Method reference: | Johnson, K., Wills, K., Butler, D., Johnson, W., and Wong, C.: Coulometric total carbon dioxide analysis for marine studies: maximizing the performance of an automated gas extraction system and coulometric detector, Mar. Chem., 44, 167-187, https://doi.org/10.1016/0304-4203(93)90201-X, 1993. 2193. |
Researcher name: | Toste Tanhua |
Researcher institution: | GEOMAR Helmholtz Centre for Ocean Research Kiel, Kiel, Germany |
Total alkalinity | |
---|---|
Abbreviation: | ALKALI |
Unit: | UMOL/KG |
Observation type: | Discrete, bottle |
Measured or calculated: | Measured |
Analyzing instrument: | VINDTA |
Type of titration: | potentiometric titration |
Cell type (open or closed): | open |
Preservation method: | 100 mL |
Uncertainty: | +/- 1.7 UMOL/KG |
Quality flag convention: | WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value |
Method reference: | Mintrop, L., Pérez, F. F., González-Dávila, M., Santana-Casiano, J. M., Körtzinger, A.: Alkalinity determination by potentiometry: intercalibration using three different methods, Cienc. Mar., 26, 23-37, 2000. 2193 |
Researcher name: | Toste Tanhua |
Researcher institution: | GEOMAR Helmholtz Centre for Ocean Research Kiel, Kiel, Germany |
SUBMITTED BY: Toste Tanhua (ttanhua@ifm-geomar.de)
SUBMISSION DATE: 2015-12-22