[BREAK Wakeup B] WorkHorse Mariner ADCP Version 52.41 Teledyne RD Instruments (c) 1996-2014 All Rights Reserved. >TS? TS 18/05/29,20:59:03 --- Time Set (yr/mon/day,hour:min:sec) >TS18/05/29, 20:58:49 >CR1 [Parameters set to FACTORY defaults] >CL0 >WD 111 000 000 >TE00:00:00.00 >CF11110 >EX00000 >EZ1011101 >CL0 >WP1 >WN70 >WS200 >WF200 >BP0 >BX2000 >WB0 >WV550 >TP00:00.80 >B? BP = 000 ----------------- Pings per Ensemble >W? Available Commands: WD 111000000 ----------- Data Out (Vel;Cor;Amp PG;St;P0 P1;P2;P3) WF 0200 ---------------- Blank After Transmit (cm) WG 000 ----------------- Percent Good Minimum (1-100%) WN 070 ----------------- Number of depth cells (1-255) WP 00001 --------------- Pings per Ensemble (0-16384) WS 0200 ---------------- Depth Cell Size (cm) WV 550 ----------------- Mode 1 Ambiguity Vel (cm/s radial) WZ 010 ----------------- Mode 5 Ambiguity Velocity (cm/s radial) W? --------------------- Display Water-Profile Help >E? EA = +00000 -------------- Heading Alignment (1/100 deg) EB = +00000 -------------- Heading Bias (1/100 deg) ED = 00000 --------------- Transducer Depth (0 - 65535 dm) ES = 35 ------------------ Salinity (0-40 pp thousand) EX = 00000 --------------- Coord Transform (Xform:Type; Tilts; 3Bm; Map) EZ = 1011101 ------------- Sensor Source (C;D;H;P;R;S;T) >C? CB = 411 ----------------- Serial Port Control (Baud [4=9600]; Par; Stop) CC = 000 000 000 --------- Choose External Devices (x;x;x x;x;x x;x;SBMC) CF = 11110 --------------- Flow Ctrl (EnsCyc;PngCyc;Binry;Ser;Rec) CK ----------------------- Keep Parameters as USER Defaults CP = 0 ------------------- PolledMode (1=ON, 0=OFF; BREAK resets) CR # --------------------- Retrieve Parameters (0 = USER, 1 = FACTORY) CS ----------------------- Go (Start Pinging) CZ ----------------------- Power Down Instrument >T? Available Commands: TB 00:00:00.00 --------- Time per Burst (hrs:min:sec.sec/100) TC 00000 --------------- Ensembles Per Burst (0-65535) TE 00:00:00.00 --------- Time per Ensemble (hrs:min:sec.sec/100) TF **/**/**,**:**:** --- Time of First Ping (yr/mon/day,hour:min:sec) TG ****/**/**,**:**:** - Time of First Ping (CCYY/MM/DD,hh:mm:ss) TP 00:00.80 ------------ Time per Ping (min:sec.sec/100) TS 18/05/29,20:58:53 --- Time Set (yr/mon/day,hour:min:sec) TT 2018/05/29,20:58:53 - Time Set (CCYY/MM/DD,hh:mm:ss) TX 00:00:00 ------------ Buffer Output Period: (hh:mm:ss) T? --------------------- Display Time Help >PS0 Instrument S/N: 24440 Frequency: 307200 HZ Configuration: 4 BEAM, JANUS Match Layer: 10 Beam Angle: 20 DEGREES Beam Pattern: CONVEX Orientation: DOWN Sensor(s): HEADING TILT 1 TILT 2 TEMPERATURE Temp Sens Offset: -0.09 degrees C CPU Firmware: 52.41 [0] Boot Code Ver: Required: 1.17 Actual: 1.17 DEMOD #1 Ver: ad48, Type: 1f DEMOD #2 Ver: ad48, Type: 1f PWRTIMG Ver: 85d3, Type: 7 Board Serial Number Data: 1D 00 00 08 14 AE 5C 09 DSP727-2001-04H B7 00 00 06 B2 EF 6D 09 PIO727-3000-00G 53 00 00 08 6C E7 83 09 CPU727-2011-00E C9 00 00 08 6C A6 EF 09 REC727-1000-04F >CF11110 > >CB511 > [BREAK Wakeup B] WorkHorse Mariner ADCP Version 52.41 Teledyne RD Instruments (c) 1996-2014 All Rights Reserved. >TS? TS 18/05/30,02:06:33 --- Time Set (yr/mon/day,hour:min:sec) > [BREAK Wakeup B] WorkHorse Mariner ADCP Version 52.41 Teledyne RD Instruments (c) 1996-2014 All Rights Reserved. >TS? TS 18/05/30,16:00:29 --- Time Set (yr/mon/day,hour:min:sec) >TS18/05/30, 16:00:28 >CR1 [Parameters set to FACTORY defaults] >CL0 >WD 111 000 000 >TE00:00:00.00 >CF11110 >EX00000 >EZ1011101 >CL0 >WP1 >WN70 >WS200 >WF200 >BP0 >BX2000 >WB0 >WV550 >TP00:00.80 >B? BP = 000 ----------------- Pings per Ensemble >W? Available Commands: WD 111000000 ----------- Data Out (Vel;Cor;Amp PG;St;P0 P1;P2;P3) WF 0200 ---------------- Blank After Transmit (cm) WG 000 ----------------- Percent Good Minimum (1-100%) WN 070 ----------------- Number of depth cells (1-255) WP 00001 --------------- Pings per Ensemble (0-16384) WS 0200 ---------------- Depth Cell Size (cm) WV 550 ----------------- Mode 1 Ambiguity Vel (cm/s radial) WZ 010 ----------------- Mode 5 Ambiguity Velocity (cm/s radial) W? --------------------- Display Water-Profile Help >E? EA = +00000 -------------- Heading Alignment (1/100 deg) EB = +00000 -------------- Heading Bias (1/100 deg) ED = 00000 --------------- Transducer Depth (0 - 65535 dm) ES = 35 ------------------ Salinity (0-40 pp thousand) EX = 00000 --------------- Coord Transform (Xform:Type; Tilts; 3Bm; Map) EZ = 1011101 ------------- Sensor Source (C;D;H;P;R;S;T) >C? CB = 411 ----------------- Serial Port Control (Baud [4=9600]; Par; Stop) CC = 000 000 000 --------- Choose External Devices (x;x;x x;x;x x;x;SBMC) CF = 11110 --------------- Flow Ctrl (EnsCyc;PngCyc;Binry;Ser;Rec) CK ----------------------- Keep Parameters as USER Defaults CP = 0 ------------------- PolledMode (1=ON, 0=OFF; BREAK resets) CR # --------------------- Retrieve Parameters (0 = USER, 1 = FACTORY) CS ----------------------- Go (Start Pinging) CZ ----------------------- Power Down Instrument >T? Available Commands: TB 00:00:00.00 --------- Time per Burst (hrs:min:sec.sec/100) TC 00000 --------------- Ensembles Per Burst (0-65535) TE 00:00:00.00 --------- Time per Ensemble (hrs:min:sec.sec/100) TF **/**/**,**:**:** --- Time of First Ping (yr/mon/day,hour:min:sec) TG ****/**/**,**:**:** - Time of First Ping (CCYY/MM/DD,hh:mm:ss) TP 00:00.80 ------------ Time per Ping (min:sec.sec/100) TS 18/05/30,16:00:32 --- Time Set (yr/mon/day,hour:min:sec) TT 2018/05/30,16:00:32 - Time Set (CCYY/MM/DD,hh:mm:ss) TX 00:00:00 ------------ Buffer Output Period: (hh:mm:ss) T? --------------------- Display Time Help >PS0 Instrument S/N: 24440 Frequency: 307200 HZ Configuration: 4 BEAM, JANUS Match Layer: 10 Beam Angle: 20 DEGREES Beam Pattern: CONVEX Orientation: DOWN Sensor(s): HEADING TILT 1 TILT 2 TEMPERATURE Temp Sens Offset: -0.09 degrees C CPU Firmware: 52.41 [0] Boot Code Ver: Required: 1.17 Actual: 1.17 DEMOD #1 Ver: ad48, Type: 1f DEMOD #2 Ver: ad48, Type: 1f PWRTIMG Ver: 85d3, Type: 7 Board Serial Number Data: 1D 00 00 08 14 AE 5C 09 DSP727-2001-04H B7 00 00 06 B2 EF 6D 09 PIO727-3000-00G 53 00 00 08 6C E7 83 09 CPU727-2011-00E C9 00 00 08 6C A6 EF 09 REC727-1000-04F >CF11110 > >CB511 > [BREAK Wakeup B] WorkHorse Mariner ADCP Version 52.41 Teledyne RD Instruments (c) 1996-2014 All Rights Reserved. >TS? TS 18/05/30,16:52:08 --- Time Set (yr/mon/day,hour:min:sec) > [BREAK Wakeup B] WorkHorse Mariner ADCP Version 52.41 Teledyne RD Instruments (c) 1996-2014 All Rights Reserved. >TS? TS 18/05/30,18:25:32 --- Time Set (yr/mon/day,hour:min:sec) >TS18/05/30, 18:25:33 >CR1 [Parameters set to FACTORY defaults] >CL0 >WD 111 000 000 >TE00:00:00.00 >CF11110 >EX00000 >EZ1011101 >CL0 >WP1 >WN70 >WS200 >WF200 >BP0 >BX2000 >WB0 >WV550 >TP00:00.80 >B? BP = 000 ----------------- Pings per Ensemble >W? Available Commands: WD 111000000 ----------- Data Out (Vel;Cor;Amp PG;St;P0 P1;P2;P3) WF 0200 ---------------- Blank After Transmit (cm) WG 000 ----------------- Percent Good Minimum (1-100%) WN 070 ----------------- Number of depth cells (1-255) WP 00001 --------------- Pings per Ensemble (0-16384) WS 0200 ---------------- Depth Cell Size (cm) WV 550 ----------------- Mode 1 Ambiguity Vel (cm/s radial) WZ 010 ----------------- Mode 5 Ambiguity Velocity (cm/s radial) W? --------------------- Display Water-Profile Help >E? EA = +00000 -------------- Heading Alignment (1/100 deg) EB = +00000 -------------- Heading Bias (1/100 deg) ED = 00000 --------------- Transducer Depth (0 - 65535 dm) ES = 35 ------------------ Salinity (0-40 pp thousand) EX = 00000 --------------- Coord Transform (Xform:Type; Tilts; 3Bm; Map) EZ = 1011101 ------------- Sensor Source (C;D;H;P;R;S;T) >C? CB = 411 ----------------- Serial Port Control (Baud [4=9600]; Par; Stop) CC = 000 000 000 --------- Choose External Devices (x;x;x x;x;x x;x;SBMC) CF = 11110 --------------- Flow Ctrl (EnsCyc;PngCyc;Binry;Ser;Rec) CK ----------------------- Keep Parameters as USER Defaults CP = 0 ------------------- PolledMode (1=ON, 0=OFF; BREAK resets) CR # --------------------- Retrieve Parameters (0 = USER, 1 = FACTORY) CS ----------------------- Go (Start Pinging) CZ ----------------------- Power Down Instrument >T? Available Commands: TB 00:00:00.00 --------- Time per Burst (hrs:min:sec.sec/100) TC 00000 --------------- Ensembles Per Burst (0-65535) TE 00:00:00.00 --------- Time per Ensemble (hrs:min:sec.sec/100) TF **/**/**,**:**:** --- Time of First Ping (yr/mon/day,hour:min:sec) TG ****/**/**,**:**:** - Time of First Ping (CCYY/MM/DD,hh:mm:ss) TP 00:00.80 ------------ Time per Ping (min:sec.sec/100) TS 18/05/30,18:25:37 --- Time Set (yr/mon/day,hour:min:sec) TT 2018/05/30,18:25:37 - Time Set (CCYY/MM/DD,hh:mm:ss) TX 00:00:00 ------------ Buffer Output Period: (hh:mm:ss) T? --------------------- Display Time Help >PS0 Instrument S/N: 24440 Frequency: 307200 HZ Configuration: 4 BEAM, JANUS Match Layer: 10 Beam Angle: 20 DEGREES Beam Pattern: CONVEX Orientation: DOWN Sensor(s): HEADING TILT 1 TILT 2 TEMPERATURE Temp Sens Offset: -0.09 degrees C CPU Firmware: 52.41 [0] Boot Code Ver: Required: 1.17 Actual: 1.17 DEMOD #1 Ver: ad48, Type: 1f DEMOD #2 Ver: ad48, Type: 1f PWRTIMG Ver: 85d3, Type: 7 Board Serial Number Data: 1D 00 00 08 14 AE 5C 09 DSP727-2001-04H B7 00 00 06 B2 EF 6D 09 PIO727-3000-00G 53 00 00 08 6C E7 83 09 CPU727-2011-00E C9 00 00 08 6C A6 EF 09 REC727-1000-04F >CF11110 > >CB511 > [BREAK Wakeup B] WorkHorse Mariner ADCP Version 52.41 Teledyne RD Instruments (c) 1996-2014 All Rights Reserved. >TS? TS 18/05/30,20:32:39 --- Time Set (yr/mon/day,hour:min:sec) > [BREAK Wakeup B] WorkHorse Mariner ADCP Version 52.41 Teledyne RD Instruments (c) 1996-2014 All Rights Reserved. >TS? TS 18/05/30,20:42:11 --- Time Set (yr/mon/day,hour:min:sec) >TS18/05/30, 20:42:11 >CR1 [Parameters set to FACTORY defaults] >CL0 >WD 111 000 000 >TE00:00:00.00 >CF11110 >EX00000 >EZ1011101 >CL0 >WP1 >WN70 >WS200 >WF200 >BP0 >BX2000 >WB0 >WV550 >TP00:00.80 >B? BP = 000 ----------------- Pings per Ensemble >W? Available Commands: WD 111000000 ----------- Data Out (Vel;Cor;Amp PG;St;P0 P1;P2;P3) WF 0200 ---------------- Blank After Transmit (cm) WG 000 ----------------- Percent Good Minimum (1-100%) WN 070 ----------------- Number of depth cells (1-255) WP 00001 --------------- Pings per Ensemble (0-16384) WS 0200 ---------------- Depth Cell Size (cm) WV 550 ----------------- Mode 1 Ambiguity Vel (cm/s radial) WZ 010 ----------------- Mode 5 Ambiguity Velocity (cm/s radial) W? --------------------- Display Water-Profile Help >E? EA = +00000 -------------- Heading Alignment (1/100 deg) EB = +00000 -------------- Heading Bias (1/100 deg) ED = 00000 --------------- Transducer Depth (0 - 65535 dm) ES = 35 ------------------ Salinity (0-40 pp thousand) EX = 00000 --------------- Coord Transform (Xform:Type; Tilts; 3Bm; Map) EZ = 1011101 ------------- Sensor Source (C;D;H;P;R;S;T) >C? CB = 411 ----------------- Serial Port Control (Baud [4=9600]; Par; Stop) CC = 000 000 000 --------- Choose External Devices (x;x;x x;x;x x;x;SBMC) CF = 11110 --------------- Flow Ctrl (EnsCyc;PngCyc;Binry;Ser;Rec) CK ----------------------- Keep Parameters as USER Defaults CP = 0 ------------------- PolledMode (1=ON, 0=OFF; BREAK resets) CR # --------------------- Retrieve Parameters (0 = USER, 1 = FACTORY) CS ----------------------- Go (Start Pinging) CZ ----------------------- Power Down Instrument >T? Available Commands: TB 00:00:00.00 --------- Time per Burst (hrs:min:sec.sec/100) TC 00000 --------------- Ensembles Per Burst (0-65535) TE 00:00:00.00 --------- Time per Ensemble (hrs:min:sec.sec/100) TF **/**/**,**:**:** --- Time of First Ping (yr/mon/day,hour:min:sec) TG ****/**/**,**:**:** - Time of First Ping (CCYY/MM/DD,hh:mm:ss) TP 00:00.80 ------------ Time per Ping (min:sec.sec/100) TS 18/05/30,20:42:15 --- Time Set (yr/mon/day,hour:min:sec) TT 2018/05/30,20:42:15 - Time Set (CCYY/MM/DD,hh:mm:ss) TX 00:00:00 ------------ Buffer Output Period: (hh:mm:ss) T? --------------------- Display Time Help >PS0 Instrument S/N: 24440 Frequency: 307200 HZ Configuration: 4 BEAM, JANUS Match Layer: 10 Beam Angle: 20 DEGREES Beam Pattern: CONVEX Orientation: DOWN Sensor(s): HEADING TILT 1 TILT 2 TEMPERATURE Temp Sens Offset: -0.09 degrees C CPU Firmware: 52.41 [0] Boot Code Ver: Required: 1.17 Actual: 1.17 DEMOD #1 Ver: ad48, Type: 1f DEMOD #2 Ver: ad48, Type: 1f PWRTIMG Ver: 85d3, Type: 7 Board Serial Number Data: 1D 00 00 08 14 AE 5C 09 DSP727-2001-04H B7 00 00 06 B2 EF 6D 09 PIO727-3000-00G 53 00 00 08 6C E7 83 09 CPU727-2011-00E C9 00 00 08 6C A6 EF 09 REC727-1000-04F >CF11110 > >CB511 > [BREAK Wakeup B] WorkHorse Mariner ADCP Version 52.41 Teledyne RD Instruments (c) 1996-2014 All Rights Reserved. >TS? TS 18/06/03,02:30:04 --- Time Set (yr/mon/day,hour:min:sec) >