CODE COUNTS FOR INPUT FILE 'co_gtspp_ct_2008.meds' CODE TABLES FROM DATABASE AS OF: Mar 18 2011 18:15:04 (20110318181504) (MAY NOT BE CURRENT) VALUES FOUND IN CODE TABLES: COUNT FIELD CODE TABLE VALUE DEFINITION -------- ------------ ---------- ---------- ---------- 2644 'Act_Code ' 'ACT ' 'CF ' Change a quality flag 26259 'Act_Code ' 'ACT ' 'CR ' Create record 6541 'Act_Code ' 'ACT ' 'DC ' Station was checked by duplicate checking software 14884 'Act_Code ' 'ACT ' 'QC ' Quality Control 33802 'Act_Parm ' 'PC_HIST ' 'RCRD ' Indicates a record has been created or actions are taken against the entire record 8775 'Act_Parm ' 'PC_PROF ' 'PSAL ' Salinity (PSU) 7751 'Act_Parm ' 'PC_PROF ' 'TEMP ' Temperature (degrees C) 16290 'D_P_Code ' 'DP ' 'P ' Independent parameter is Pressure 6541 'Data_Avail ' 'AVAIL ' 'A ' Available 6541 'Data_Type ' 'TYPE ' 'CT ' CTD data, up or down 71338 'Depres_Q ' 'QUAL ' '0 ' No quality control (QC) has been performed on this element. 1118458 'Depres_Q ' 'QUAL ' '1 ' QC has been performed; element appears to be correct. 3622 'Depres_Q ' 'QUAL ' '4 ' QC has been performed; element appears to be erroneous. 1117 'Digit_Code ' 'DIGMC ' '7 ' Digitized at regular depth intervals (equivalent to k1=7 for BATHY/TESAC data) 15173 'Digit_Code ' 'DIGMC ' '8 ' Digitized at inflexion points (equivalent to k1=8 for BATHY/TESAC data) 16290 'Dup_flag ' 'DUP ' 'N ' Parameter is not a duplicate 12358 'Ident_Code ' 'IDENT ' 'IF ' IFREMER, France 32800 'Ident_Code ' 'IDENT ' 'NO ' NODC (Washington) 5170 'Ident_Code ' 'IDENT ' 'TC ' TOGA Subsurface Data Centre (France) 12219 'PRC_Code ' 'PRC ' 'COOA ' Coriolis Objective Analysis 2505 'PRC_Code ' 'PRC ' 'CVQC ' Coriolis Visual Quality Control tool 1663 'PRC_Code ' 'PRC ' 'OA ' Objective Analysis performed on this station by Coriolis 1141 'PRC_Code ' 'PRC ' 'SCOO ' Coriolis Visual Quality Control tool (Scoop2) 6636 'PRC_Code ' 'PRC ' 'cv02 ' NODC convert IFREMER MEDSASCII to GTSPP MEDSASCII format 6541 'PRC_Code ' 'PRC ' 'edes ' NODC Exact duplicate Exclusion Scanner, reads MEDS-ASCII file, scans database, eliminates exact duplicates from output file 6541 'PRC_Code ' 'PRC ' 'tstc ' NODC test of codes in a MEDS-ASCII file 13082 'PRC_Code ' 'PRC ' 'tstm ' NODC format test of a MEDS-ASCII data file 352807 'Prof_Q_Parm ' 'QUAL ' '0 ' No quality control (QC) has been performed on this element. 804379 'Prof_Q_Parm ' 'QUAL ' '1 ' QC has been performed; element appears to be correct. 10 'Prof_Q_Parm ' 'QUAL ' '2 ' QC has been performed; element appears to be inconsistent with other elements. 1789 'Prof_Q_Parm ' 'QUAL ' '3 ' QC has been performed; element appears to be doubtful. 24683 'Prof_Q_Parm ' 'QUAL ' '4 ' QC has been performed; element appears to be erroneous. 13 'Prof_Q_Parm ' 'QUAL ' '5 ' The value has been changed as a result of QC. 3 'Prof_Q_Parm ' 'QUAL ' '6 ' Reserved. 4 'Prof_Q_Parm ' 'QUAL ' '7 ' Reserved. 9495 'Prof_Q_Parm ' 'QUAL ' '8 ' QC has been performed by the originator. 235 'Prof_Q_Parm ' 'QUAL ' '9 ' The value of the element is missing. 2995 'Prof_Type ' 'PC_PROF ' 'CNDC ' Electrical conductivity (mho per metre) 1147 'Prof_Type ' 'PC_PROF ' 'DOXY ' DISSOLVED OXYGEN (mmol/m**3) 6007 'Prof_Type ' 'PC_PROF ' 'PSAL ' Salinity (PSU) 6141 'Prof_Type ' 'PC_PROF ' 'TEMP ' Temperature (degrees C) 2995 'Profile_Type' 'PC_PROF ' 'CNDC ' Electrical conductivity (mho per metre) 1147 'Profile_Type' 'PC_PROF ' 'DOXY ' DISSOLVED OXYGEN (mmol/m**3) 6007 'Profile_Type' 'PC_PROF ' 'PSAL ' Salinity (PSU) 6141 'Profile_Type' 'PC_PROF ' 'TEMP ' Temperature (degrees C) 32 'Q_Date_Time ' 'QUAL ' '0 ' No quality control (QC) has been performed on this element. 6498 'Q_Date_Time ' 'QUAL ' '1 ' QC has been performed; element appears to be correct. 11 'Q_Date_Time ' 'QUAL ' '3 ' QC has been performed; element appears to be doubtful. 32 'Q_Pos ' 'QUAL ' '0 ' No quality control (QC) has been performed on this element. 5821 'Q_Pos ' 'QUAL ' '1 ' QC has been performed; element appears to be correct. 22 'Q_Pos ' 'QUAL ' '3 ' QC has been performed; element appears to be doubtful. 666 'Q_Pos ' 'QUAL ' '4 ' QC has been performed; element appears to be erroneous. 400 'Q_Record ' 'QUAL ' '0 ' No quality control (QC) has been performed on this element. 4464 'Q_Record ' 'QUAL ' '1 ' QC has been performed; element appears to be correct. 194 'Q_Record ' 'QUAL ' '3 ' QC has been performed; element appears to be doubtful. 954 'Q_Record ' 'QUAL ' '4 ' QC has been performed; element appears to be erroneous. 508 'Q_Record ' 'QUAL ' '8 ' QC has been performed by the originator. 21 'Q_Record ' 'QUAL ' '9 ' The value of the element is missing. 6636 'SRFC_Code ' 'PC_CODE ' 'ACCS ' Accession number 2876 'SRFC_Code ' 'PC_CODE ' 'CRC$ ' 32 bit circular redundancy code (Special IGOSS Indicator) 6541 'SRFC_Code ' 'PC_CODE ' 'GCLL ' Call Sign 6541 'SRFC_Code ' 'PC_CODE ' 'LDAT ' Load Date at NODC 6541 'SRFC_Code ' 'PC_CODE ' 'PFR$ ' XBT probe type, fall rate equation and recorder type (WMO code 1770 and 4770) 6541 'SRFC_Code ' 'PC_CODE ' 'PLAT ' Platform 6541 'SRFC_Code ' 'PC_CODE ' 'TCID ' IFREMER TOGA Center Unique Database ID 6541 'SRFC_Parm ' 'SC_PEQ$ ' '830 ' CTD 6541 'SRFC_Parm ' 'SC_RCT$ ' '99 ' Unknown 13177 'SRFC_Q_Parm ' 'QUAL ' '0 ' No quality control (QC) has been performed on this element. 29040 'SRFC_Q_Parm ' 'QUAL ' '1 ' QC has been performed; element appears to be correct. 2995 'Standard ' 'STD_CNDC ' '4 ' unknown accuracy 1147 'Standard ' 'STD_DOXY ' '4 ' In situ sensor, unknown accuracy (microg-at/l == mmol/m**3) 6007 'Standard ' 'STD_PSAL ' '4 ' unknown accuracy (PSU assumed) 6141 'Standard ' 'STD_TEMP ' '4 ' unknown accuracy (degrees C) 6461 'Stream_Ident' 'IDENT ' 'IF ' IFREMER, France 80 'Stream_Ident' 'IDENT ' 'TC ' TOGA Subsurface Data Centre (France) 6541 'Stream_Ident' 'TYPE ' 'CT ' CTD data, up or down 6541 'Uflag ' 'UFLAG ' 'U ' Add this station to file during update --------------------------------------------------------------