CODE COUNTS FOR INPUT FILE 'co_gtspp_re_2007.meds' CODE TABLES FROM DATABASE AS OF: Mar 18 2011 19:15:59 (20110318191559) VALUES FOUND IN CODE TABLES: COUNT FIELD CODE TABLE VALUE DEFINITION -------- ------------ ---------- ---------- ---------- 2223 'Act_Code ' 'ACT ' 'CF ' Change a quality flag 2246 'Act_Code ' 'ACT ' 'CR ' Create record 839 'Act_Code ' 'ACT ' 'QC ' Quality Control 3085 'Act_Parm ' 'PC_HIST ' 'RCRD ' Indicates a record has been created or actions are taken against the entire record 2223 'Act_Parm ' 'PC_PROF ' 'TEMP ' Temperature (degrees C) 1123 'D_P_Code ' 'DP ' 'D ' Independent parameter is Depth 1123 'Data_Avail ' 'AVAIL ' 'A ' Available 1123 'Data_Type ' 'TYPE ' 'ML ' Minilog 146044 'Depres_Q ' 'QUAL ' '1 ' QC has been performed; element appears to be correct. 1123 'Digit_Code ' 'DIGMC ' '8 ' Digitized at inflexion points (equivalent to k1=8 for BATHY/TESAC data) 1123 'Dup_flag ' 'DUP ' 'N ' Parameter is not a duplicate 3062 'Ident_Code ' 'IDENT ' 'IF ' IFREMER, France 2246 'Ident_Code ' 'IDENT ' 'NO ' NODC (Washington) 2218 'PRC_Code ' 'PRC ' 'CVQC ' Coriolis Visual Quality Control tool 844 'PRC_Code ' 'PRC ' 'SCOO ' Coriolis Visual Quality Control tool (Scoop2) 1123 'PRC_Code ' 'PRC ' 'cv02 ' NODC convert IFREMER MEDSASCII to GTSPP MEDSASCII format 1123 'PRC_Code ' 'PRC ' 'tstm ' NODC format test of a MEDS-ASCII data file 145236 'Prof_Q_Parm ' 'QUAL ' '1 ' QC has been performed; element appears to be correct. 606 'Prof_Q_Parm ' 'QUAL ' '3 ' QC has been performed; element appears to be doubtful. 202 'Prof_Q_Parm ' 'QUAL ' '4 ' QC has been performed; element appears to be erroneous. 1123 'Prof_Type ' 'PC_PROF ' 'TEMP ' Temperature (degrees C) 1123 'Profile_Type' 'PC_PROF ' 'TEMP ' Temperature (degrees C) 1123 'Q_Date_Time ' 'QUAL ' '1 ' QC has been performed; element appears to be correct. 1102 'Q_Pos ' 'QUAL ' '1 ' QC has been performed; element appears to be correct. 21 'Q_Pos ' 'QUAL ' '4 ' QC has been performed; element appears to be erroneous. 978 'Q_Record ' 'QUAL ' '1 ' QC has been performed; element appears to be correct. 61 'Q_Record ' 'QUAL ' '3 ' QC has been performed; element appears to be doubtful. 84 'Q_Record ' 'QUAL ' '4 ' QC has been performed; element appears to be erroneous. 1123 'SRFC_Code ' 'PC_CODE ' 'ACCS ' Accession number 1123 'SRFC_Code ' 'PC_CODE ' 'GCLL ' Call Sign 1123 'SRFC_Code ' 'PC_CODE ' 'IST$ ' Instrument name 1123 'SRFC_Code ' 'PC_CODE ' 'PLAT ' Platform 1123 'SRFC_Code ' 'PC_CODE ' 'PRJ$ ' Project Name 1123 'SRFC_Code ' 'PC_CODE ' 'TCID ' IFREMER TOGA Center Unique Database ID 1123 'SRFC_Parm ' 'SC_IST$ ' 'SP2T ' TD Recorder (temperature, depth) NKE Instrumentation (France) 3369 'SRFC_Q_Parm ' 'QUAL ' '0 ' No quality control (QC) has been performed on this element. 3369 'SRFC_Q_Parm ' 'QUAL ' '1 ' QC has been performed; element appears to be correct. 1123 'Standard ' 'STD_TEMP ' '4 ' unknown accuracy (degrees C) 1123 'Stream_Ident' 'IDENT ' 'IF ' IFREMER, France 1123 'Stream_Ident' 'TYPE ' 'ML ' Minilog 1123 'Uflag ' 'UFLAG ' 'U ' Add this station to file during update --------------------------------------------------------------